87b2365c-0956-4fd8-bff9-efcda057c344.png
1622617763(1).png
1622618431(1).png
1622617994(1).png
+
  • 87b2365c-0956-4fd8-bff9-efcda057c344.png
  • 1622617763(1).png
  • 1622618431(1).png
  • 1622617994(1).png

Cold storage transformation, cold storage construction


Classification:

Classification:

Cold storage construction, chip cold storage, high precision cold storage

Cooperate

Detailed introduction


Analysis of cold storage installation plan

69563b2a-4be3-42b7-ab72-468a872e732a

No.

Operating temperature

Volume

Host

Library No. 1

10℃ ~ 15℃

(6X5X3)

Low temperature frequency conversion compression Condensing Unit 15P, 2 sets

Storage product: chip raw material liquid

Library No. 2

0℃ ~ 4℃

(6X6X3)

Library No. 3

-15℃ ~ -20℃

3X4X3

Library No. 4

-15℃ ~ -20℃

3X3X3

1. Installation process: The original system consists of one 15P parallel unit and one 7.5P cryogenic unit

2, product particularity: the system must ensure that two sets of indoor air coolers run online at the same time

3, the installation process must ensure that: each library has two refrigeration system operation (that is, the main and standby are normal at the same time)

Two, design optimization:

1, indoor air cooler installation on the same side (because the library body is relatively small, the opposite installation will cause one fan defrosting, another fan directly blowing cold, mutual defrosting effect is not good;

2, high temperature storage air return port installed pressure difference controller, adjust the high temperature storage air return pressure;

3. Set oil return bay in each group of evaporator, oil return bay in main circuit and oil storage tank in compressor host;

4, the system adopts PLC control, optimize the dual machine process control, automatic alternating operation,

5, the refrigeration host adopts pressure control; Indoor air cooler is controlled by temperature and solenoid valve,

6, indoor air cooler synchronous defrosting operation design, defrosting interval 2h ~ 3h reset another

7, enhance insulation, ensure the library temperature, reduce the frequent operation of the compressor, (the original system is old, insulation performance is poor)

8, adjust the expansion valve opening, to meet the minimum load cold storage running compressor frost,

9. Reserve enough inclination for condensate drain pipe to drain pipe from low temperature warehouse to high temperature warehouse (heating belt)

(the original design is to distribute pipes from high temperature warehouse to low temperature warehouse, resulting in ice blocking of pipes and serious frosting of air cooler),

10, the compressor stop pressure is controlled by micro positive pressure, or vacuum negative pressure operation (to ensure that the system stops, oil return)

11, finally pay attention to construction, construction progress standard

(It is not recommended to use one machine to run several libraries, which is not energy-saving, and requires high reliability of the compressor and frequent operation of the compressor)

SAF Coolest v1.2 设置面板APQSS-ASNW-NSZSE-AVQ

图片ALT信息: Ctelin
违禁词: 第一,最,一流,领先,独一无二,王者,龙头,领导者,极致,
修改浏览器滑块样式: 4px,4px,#0c3676

无数据提示

Sorry,There is currently no content in the current column!

You can view other columns or return to Home

SVG图标库请自行添加图标,用div包起来,并命名使用