Variable frequency screw chiller


key word:

Frequency conversion

water flow

The necessity of frequency conversion chiller

Inquiry

Detailed introduction


• Necessity of frequency conversion chiller --

• Because the outdoor temperature (dry bulb/wet bulb temperature) varies with time and season

• Only 1% of the operating time of the refrigeration unit is in full load operation under the design condition

• Frequency conversion chiller can make full use of the advantages brought by low cooling water temperature (low head - speed reduction - energy consumption reduction)

• York YVWH variable frequency screw chiller is fully factory assembled, including evaporator, condenser, compressor, motor, lubrication system, LCD microcomputer control center and complete unit, all nozzles and wiring, and provides the first charge of refrigerant and lubricating oil for each unit.

• High efficiency and energy saving: The partial load efficiency (IPLV or NPLV) of YVWA is 30% higher than that of conventional chiller units, which can significantly reduce the operating energy consumption and effectively shorten the return on investment of the project.

• Environmental refrigerant, benefit mankind: YVWA adopts HFC-134a environmental refrigerant, and through the application of mixed falling film evaporator, greatly reduce the refrigerant charging amount; The efficient YVWA series unit indirectly reduces the CO2 emission of the power plant and reduces the impact on the atmospheric environment by reducing the power consumption. Help you achieve LEED certification.

• Wide application: YVWA unit can adopt cooling tower, evaporative condenser, dry cooler and other cooling methods, widely suitable for ice storage, heat recovery, heat pump and other applications, can meet the various needs of customers.

• High efficiency heat transfer, excellent performance: new hybrid falling film evaporator and high efficiency heat transfer copper tube to improve efficiency; Water side and refrigerant side strengthen heat transfer, reduce unit energy consumption and pipe scaling.

• Excellent electrical characteristics: The YVWA variable frequency compressor provides a soft start without current shock. The unit's starting current never exceeds its nominal current value at full load, which reduces the customer's power package cost. The motor does not overheat during startup and can be quickly restarted in the event of a power failure shutdown.

Model number

kW

Input power

Full load current

Evaporator

condenser

Size

Water flow l/s

Water flow l/s

Long mm

Width mm

High mm

YVWABDBCFXJEASIASA

521

99

158

24.9 31.1

3002

1413

1846

YVWABDBBGXJEASIASA

596

117

187

28.5 35.6

3002

1413

1846

YVWACBCBGXJEASIASA

642

121

194

30.7 38.3

3612

1413

1846

YVWACDCBGXJEASIASA

689

131

209

32.9 41.2

3612

1413

1846

YVWAM2M3EEAEASIASA

778

153

244

37.2 46.4

4274

1405

1835

YVWAMBMCEEAEASIASA

819

147

235

39.1 48.9

4274

1405

1835

YVWAM3M3EEAEASIASA

823

162

258

39.3 49.2  

Related products


Consultation quotation

*Note: Please make sure to fill in the information accurately and maintain smooth communication. We will contact you as soon as possible

SAF Coolest v1.2 设置面板APQSS-ASNW-NSZSE-AVQ

图片ALT信息: Ctelin
违禁词: 第一,最,一流,领先,独一无二,王者,龙头,领导者,极致,
修改浏览器滑块样式: 4px,4px,#0c3676

无数据提示

Sorry,There is currently no content in the current column!

You can view other columns or return to Home

SVG图标库请自行添加图标,用div包起来,并命名使用