Model |
195HE |
220HE |
260HE |
300HE |
350HE |
390HE |
440HE |
455HE |
515HE |
|
Rated cooling capacity (KW) |
196 |
213 |
253 |
310 |
346 |
386 |
429 |
451 |
521 |
|
Rated input power (KW) |
63.8 | 67.2 | 83.5 |
100 |
111.7 | 127.5 | 141.1 |
147 |
170.3 |
|
• Energy efficient • High efficiency scroll compressor designed for R410A.• Multi-link independent system design, low starting current, more stable system. • Industry-leading full-load efficiency and partial load efficiency, lower annual operating costs |
|||||||||
|
Stable and reliable Industry unique IP55 electric control box design makes the unit protection more comprehensive. • The combination of standard high temperature components and low temperature components can effectively ensure the unitStable operation at -17.8 ℃ to 51.7 ℃ ambient temperature. • The refrigerant system is welded. All welding is done in the factory without on-site operation, which greatly reduces the potential for leakage.have spent The unit is equipped with standard compressor heater, which can effectively prevent compressor liquid blow |
|||||||||
|
Powerful troubleshooting function • The controller can monitor the operating parameters of the unit in real time and provide necessary alarm signals, and support remote fault alarm.• After the system fault is rectified, the system can be automatically restarted or manually restarted for convenience. Complete protection function • The temperature of chilled water outlet provided by the unit is too low, the voltage is too low, and the flow rate of chilled water is too low,High exhaust pressure, low inspiratory pressure perfect mechanical and electrical protection. Leading expansion function • Provide Modbus and BACnet open protocols for users to choose from |
|||||||||
|
Advantages of air cooled Vortex chiller : 1, do not need to occupy a special machine room, and do not need to install cooling tower and pump room, convenient operation, without professional maintenance; 2. Air cooled unit has no cooling water system, saving urban water; (The floating water loss of water cooling tower of water cooling unit is 5‰ per hour) 3. Lower maintenance cost than water cooling unit; 4, multi-compressor control energy-saving (multi-compressor system, according to the load system to start the compressor) Disadvantages of air cooled vortex chiller; 1, generally installed in the outdoor, the operation environment is relatively harsh, in the maintenance and reliability are not as convenient as water cooled chiller; 2. The high condensing temperature reduces the operating efficiency of the refrigeration unit; 3. The high temperature refrigeration effect is poor in summer; |
|||||||||
Related products
Consultation quotation
*Note: Please make sure to fill in the information accurately and maintain smooth communication. We will contact you as soon as possible
National Service Hotline
Address: No. 66, Shuangfu 1st Road, Chenghua District, Chengdu
SAF Coolest v1.2 设置面板 APQSS-ASNW-NSZSE-AVQ
无数据提示
Sorry,There is currently no content in the current column!
You can view other columns or return to Home